Fleetwood Recall 76V020000: Visibility, Defroster/defogger/hvac System
NHTSA recall 76V020000 · announced February 11, 1976 · filed by Fleetwood Ent., Inc. · 932 units affected
Official NHTSA recall notice →
Notes
FLEETWOOD CAMPAIGN NO N/A.TRAVEL TRAILERS.POSSIBILITY THAT THE FLUE OUTLETFITTING IS NOT LONG ENOUGH TO PROVIDE CONNECTION OF THE INSULATING SLEEVE TOTHE FURNACE OUTER CASE AND IN SOME CASES NOT LONG ENOUGH TO PROVIDE CONNECTIONTO THE FLUE TUBE WHERE IT EMERGES FROM FURNACE CASE.THESE CONDITIONS MAYPERMIT TEMPERATURES ON THE COMBUSTIBLE TRAILER WALL IN EXCESS OF THE FURNACELISTED REQUIREMENTS AND/OR PRODUCTS OF COMBUSTION TO BE DISCHARGED INSIDE THETRAILER (CORRECT BY INSPECTING AND INSTALLING OF NEW INSULATING SLEEVE WHERENECESSARY).
Vehicles covered by this recall
- 1975 Fleetwood Prowler
- 1976 Fleetwood Prowler
- 1975 Fleetwood Terry
- 1976 Fleetwood Terry
- 1975 Fleetwood Wilderness
- 1976 Fleetwood Wilderness