Amprobe Recalls Clamp Meters Due to Shock Hazard

CPSC recall 07130 · announced March 15, 2007 · Amprobe Test Tools · 70,000 units affected

The product

Only Amprobe brand digital clamp meter models ACD-10PRO, ACD-10 TRMS-PRO, ACD-14 and ACD-14TRMS, except those model numbers followed by "FX" or "PLUS," are included in the recall. "Amprobe" and the model numbers are printed on the front of the units. These clamp meters measure 0 to 600 volts alternating current (VAC), and 0 to 600 volts direct current (VDC). In addition, they measure 0 to 400 amps alternating current. The tester body is red and gray and measures 7-1/2 inches in length by 2-1/2 inches in width by 1-1/4 inches thick.

The hazard

The meters can fail to give an appropriate voltage reading, resulting in the operator believing the electrical power is off, which can pose a risk of shock, electrocution, or thermal burn hazard.

What to do (per CPSC)

Consumers should stop using these recalled clamp meters immediately and contact Amprobe for a free replacement clamp meter.

Official CPSC recall notice →

Notes

Incidents (per CPSC): Amprobe is aware of one report of a clamp meter displaying an incorrect voltage reading. No injuries have been reported.
Sold at: Industrial distributors, electrical wholesalers and hardware stores nationwide from January 2002 through December 2006 for about $100.
Consumer contact: For additional information, contact Amprobe at (800) 350-8661 between 7 a.m. and 4 p.m. PT Monday through Friday or visit the firm's Web site at www.amprobe.com/recall

Source: U.S. Consumer Product Safety Commission public recall data. This page reports official records and is not legal, medical, or repair advice.